亚洲国产精品二区久久,日本美女后入式午夜视频在线观看,国产污视频在线观看,欧美日韩国产精品中文字幕在线观看

行業(yè)產(chǎn)品

  • 行業(yè)產(chǎn)品

廈門慧嘉生物科技有限公司


當(dāng)前位置:廈門慧嘉生物科技有限公司>資料下載>CSB-E07965h人前列腺素E2(PGE2)ELISA試劑盒說明書
資料下載

CSB-E07965h人前列腺素E2(PGE2)ELISA試劑盒說明書

閱讀:379發(fā)布時間:2011-12-20

  • 提供商

    廈門慧嘉生物科技有限公司

  • 資料大小

    75.3KB

  • 資料圖片

  • 下載次數(shù)

    105次

  • 資料類型

    WORD 文檔

  • 瀏覽次數(shù)

    379次

  • 免費(fèi)下載

    點(diǎn)擊下載


 

 Human Prostaglandin E2 (PGE2)ELISA Kit
Catalog No. CSB-E07965h
(96T)
This immunoassay kit allows for the in vitro quantitative determination of human PGE2 concentrations in serum, plasma .
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門慧嘉生物長期經(jīng)營ELISA試劑盒及Santa/Abcam抗體、Peprotech細(xì)胞因子、Sigma/Amresco/Qiagen、Axygen耗材等生物試劑產(chǎn)品。誠信經(jīng)營,價格實(shí)惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:  :  1048735792 或登陸/download(向客服人員索取原版說明書)
 
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with a goat-anti-rabbit antibody. Standards or samples are then added to the appropriate microtiter plate wells with a HRP-conjugated PGE2 and antibody preparation specific for PGE2 and incubated. Then substrate solutions are added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ±2 nm. The concentration of PGE2 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
DETECTION RANGE
1.2 pg/ml-300 pg/ml. The standard curve concentrations used for the ELISA’s were 300 pg/ml, 75 pg/ml, 18.75 pg/ml, 4.65 pg/ml, 1.2 pg/ml.
SPECIFICITY
This assay recognizes human PGE2. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of human PGE2 is typically less than
0.75 pg/ml.
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.
MATERIALS PROVIDED
Reagent Quantity
Assay plate 1 Standards (S1-S5) 5 x 0.5 ml HRP-conjugate 1 x 6 ml Antibody 1 x 6 ml
1 x 15 ml
Wash Buffer
(20×concentrate) Substrate A 1 x 7 ml Substrate B 1 x 7 ml Stop Solution 1 x 7 ml

Standard
S 1
S 2
S 3
S 4
S 5
Concentration (pg/ml)
1.2
4.65
18.75
75
300

STORAGE
1.    Unopened test kits should be stored at 2-8?C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date.
2.    Opened test plate should be stored at 2-8?C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3.    A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
TECHNICAL HINTS
Bring all reagents and plate to room temperature for at least 30 minutes before use. Unused wells need store at 2-8and avoid sunlight.
1         Wash Buffer If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have compley dissolved. Dilute 15 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 300 ml of Wash Buffer.
2         To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
3         When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision.
4         To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Sealers can not be reused.
5         Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue.
6         Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye,
hand, face, and clothing protection when using this material.
OTHER SUPPLIES REQUIRED
1          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2          Pipettes and pipette tips.
3          Deionized or distilled water.
4          Squirt bottle, manifold dispenser, or automated microplate washer.
5          An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
 
SAMPLE COLLECTION AND STORAGE
Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 x g. Remove serum and assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay.Avoid repeated freeze-thaw cycles.
Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
 
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
1         Set a Blank well without any solution. Add 50μl of Standard or Sample per well. Standards need test in duplicate.
2         Add 50μl of HRP-conjugate to each well (not to Blank well), then add 50μl Antibody to each well. Mix well and then incubate for 1 hour at 37°C.
3         Fill each well with Wash Buffer (about 200μl), stay for 10 seconds and Spinning. Repeat the process for a total of three washes. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
4         Add 50μl of Substrate A and Substrate B to each well, mix well. Incubate for 15 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark.
5         Add 50μl of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
6         Determine the optical density of each well within 10 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Using the professional soft "Curve Exert 1.3" to make a standard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each standard, Blank, and sample and subtract the optical density of Blank. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the PGE2 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
1          The kit should not be used beyond the expiration date on the kit label.
2          Do not mix or substitute reagents with those from other lots or sources.
3          If samples generate values higher than the highest standard, dilute the samples with the appropriate Diluent and repeat the assay.
4          Any variation in operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding.
5          This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.

環(huán)保在線 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.kytsldc.cn,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),環(huán)保在線對此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~
被几个大屌老外轮操| 中文字幕在线观看第二页| 久久久久久久 亚洲精品| 男的日女生批网页| 日韩精品一区av在线| 香蕉国产精品偷在线| 日本精品高清在线观看| 中文字幕在线观一区二区| 正在播放老熟女人与小伙| 亚洲精品一区二区精华液| 国产女明星一级毛片| 欧美高清在线观看一区二区三区| 日本二区在线观看| 看看美日韩操逼吧| 操国产骚逼逼逼逼逼逼逼| 把韩国美女操出水| 国产一区二区三区免费观在线| 亚洲AV天堂一区二区香蕉| 美女张开腿让男人桶91| 激情久久久久久久久久久| 少妇无套带白浆嗯呢啊污| 中文字幕一区二区三区中文字幕| 亚洲一区亚洲二区在线观看| 男人吃奶大鸡巴操逼视频| 黄色视频网在线观看| 大黑鸡巴操模特骚B| 男女边吃奶边做边爱视频| 精品一二三四区中文字幕| 精品精品国产一区二区性色av| 国产品无码一区二区三区在线| 大鸡鸡插我骚逼视频| 老熟妇高潮一区二区高清视频| 在线观看日韩欧美| 欧美精品一区二区三区四区五区| 99精品一级欧美片免费| 男人插女人视频软件| 男人把昆吧放女人屁股里| 欧美在线A片一区二区三区| 99久久久国产精品k影| 冷色系的发色有哪些颜色| 国产精品碰碰现在自|