亚洲国产精品二区久久,日本美女后入式午夜视频在线观看,国产污视频在线观看,欧美日韩国产精品中文字幕在线观看

行業(yè)產(chǎn)品

  • 行業(yè)產(chǎn)品

廈門(mén)慧嘉生物科技有限公司


當(dāng)前位置:廈門(mén)慧嘉生物科技有限公司>資料下載>CSB-E08119h人胰高血糖素樣肽1(GLP-1)ELISA試劑盒說(shuō)明書(shū)
資料下載

CSB-E08119h人胰高血糖素樣肽1(GLP-1)ELISA試劑盒說(shuō)明書(shū)

閱讀:536發(fā)布時(shí)間:2011-12-30

  • 提供商

    廈門(mén)慧嘉生物科技有限公司

  • 資料大小

    121.3KB

  • 資料圖片

  • 下載次數(shù)

    106次

  • 資料類(lèi)型

    WORD 文檔

  • 瀏覽次數(shù)

    536次

  • 免費(fèi)下載

    點(diǎn)擊下載


 

 Human Glucagon­like Peptide­1 (GLP­1)ELISA Kit
Catalog No. CSB­E08119h
(96T)
This immunoassay kit allows for the in vitro quantitative determination of human GLP­1 concentrations in serum, plasma a-n-d other biological fluids.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門(mén)慧嘉生物長(zhǎng)期經(jīng)營(yíng)ELISA試劑盒及Santa/Abcam抗體、Prospec細(xì)胞因子、Sigma/Amresco/Qiagen、Axygen耗材等生物試劑產(chǎn)品。誠(chéng)信經(jīng)營(yíng),價(jià)格實(shí)惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來(lái)詢!:   :  1048735792 或登陸/download(向客服人員索取原版說(shuō)明書(shū))
 
INTRODUCTION
Glucagon Like Peptide­1 (GLP­1) is a peptide hormone from the intestinal mucosa, which is produced from its precursor, proglucagon by post transnational processing. The mammalian proglucagon is synthesized in the neuroendocrine L­cell of the intestine a-n-d the alpha­cells of the pancreas. It contains within its structure the sequences of glucagon a-n-d two glucagon­like peptides (GLP­1 a-n-d GLP­2) in ta-n-dem flanked at their amino a-n-d carboxyl termini by dibasic residues. GLP­1 is a 37 amino acids peptide a-n-d produced in the small intestine a-n-d in the pancreas in the rat, in either C­terminal­amidated on glycine­extended form. GLP1 (7­36) amide a-n-d its receptor are present in several brain regions a-n-d may play a role in the physiological control of feeding. Several reports have been presented as follows as to the biological activities of GLP­1. GLP­1 (7­37) a-n-d (7­36) amide is known as one of the most potent insulin secretagogues.
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre­coated with an antibody specific to GLP­1. Sta-n-dards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)­conjugated monoclonal antibody preparation specific for GLP­1 a-n-d incubated. Then substrate solution A a-n-d B are added to each well. Only those wells that contain GLP­1, HRP­conjugated antibody will exhibit a change in color. The enzyme­substrate reaction is terminated by the addition of a sulphuric acid solution a-n-d the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of GLP­1 in the samples is then determined by comparing the O.D. of the samples to the sta-n-dard curve.
DETECTION RANGE
2.3ng/ml­40ng/ml. The sta-n-dard curve concentrations used for the ELISA’s were 40ng/ml,22.8ng/ml,9.2ng/ml, 4.6ng/ml, 2.3ng/ml
SPECIFICITY
This assay recognizes recombinant a-n-d natural human GLP­1. No significant cross­reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of human GLP­1 is typically less than 1.4ng/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest concentration that could be differentiated from zero.
MATERIALS PROVIDED STORAGE

Reagent
Quantity
 
Assay plate
1
 
Standard(S1­S5)
5
 
HRP­conjugate
1 x 6 ml
 
 
1 x 15 ml
 
Wash Buffer
 
 
 
(20×concentrate)
 
Substrate A
1 x 7 ml
 
Substrate B
1 x 7 ml
 
Stop Solution
1 x 7 ml
 

Standard
Standard 1
Standard 2
Standard 3
Standard 4
Standard 5
Concentration (ng/ml)
2.3
4.6
9.2
22.8
40

 
1          Unopened test kits should be stored at 2­8°C upon receipt a-n-d the microtiter plate should be kept in a sealed bag to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date.
2          Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3          A microtiter plate reader with a ba-n-dwidth of 10 nm or less a-n-d an optical density range of 0­3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
REAGENT PREPARATION
1          Bring all reagents a-n-d plate to room temperature for at least 30 minutes before use. Unused wells need store at 2­8°C a-n-d avoid sunlight.
2          Wash Buffer If crystals have formed in the concentrate, warm to room temperature a-n-d mix gently until the crystals have compley dissolved. Dilute 15 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 300 ml of Wash Buffer.
3          Sta-n-dard Reconstitute the Sta-n-dards with 0.5 ml of ddH2O, respectively. Allow the sta-n-dard to sit for a minimum of 15 minutes with gentle agitation prior to use.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, ha-n-d, face, a-n-d clothing protection when using this material.
OTHER SUPPLIES REQUIRED
1           Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2           Pipettes a-n-d pipette tips.
3           Deionized or distilled water.
4           Squirt bottle, manifold dispenser, or automated microplate washer.
 
SAMPLE COLLECTION A-N-D STORAGE
Serum Use a serum separator tube (SST) a-n-d allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum a-n-d assay immediay or aliquot a-n-d store samples at ­20° C. Avoid repeated freeze­thaw cycles.
Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot a-n-d store samples at ­20°C. Avoid repeated freeze­thaw cycles.
 
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents a-n-d samples to room temperature before use. It is recommended that all samples, sta-n-dards, a-n-d controls be assayed in duplicate.
1          Set a Blank well without any solution. Add 50µl of Sta-n-dard or Sample per well. Sta-n-dard need test in duplicate.
2          Add 50µl of HRP­conjugate to each well (not to Blank well). Mix well a-n-d then incubate for 2 hour at 37°C.
3          Complete remove the liquid. Then fill each well with Wash Buffer (about 200µl), stay for 10 seconds a-n-d Spinning. Repeat the process for a total of three washes. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate a-n-d blot it against clean paper towels.
4          Add 50µl of Substrate A a-n-d 50µl of Substrate B to each well, mix well. Incubate for 15 minutes at 37°C. Keeping the plate away from drafts a-n-d other temperature fluctuations in the dark.
5          Add 50µl of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
6          Determine the optical density of each well within 10 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Average the duplicate readings for each sta-n-dard, control, a-n-d sample a-n-d subtract the average zero sta-n-dard optical density. Create a sta-n-dard curve by reducing the data using computer software capable of generating a four parameter logistic (4­PL) curve­fit. As an alternative, construct a sta-n-dard curve by plotting the mean absorbance for each sta-n-dard on the y­axis against the concentration on the x­axis a-n-d draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the GLP­1 concentrations versus the log of the O.D. a-n-d the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the sta-n-dard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
1           The kit should not be used beyond the expiration date on the kit label.
2           Do not mix or substitute reagents with those from other lots or sources.
3           It is important that the Calibrator Diluent selected for the sta-n-dard curve be consistent with the samples being assayed.
4           If samples generate values higher than the highest sta-n-dard, dilute the samples with the appropriate Calibrator Diluent a-n-d repeat the assay.
5           Any variation in Sta-n-dard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, a-n-d kit age can cause variation in binding.
6           This assay is designed to eliminate interference by soluble receptors, binding proteins, a-n-d other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
 
TECHNICAL HINTS
1           When mixing or reconstituting protein solutions, always avoid foaming.
2           To avoid cross­contamination, change pipette tips between additions of each sta-n-dard level, between sample additions, a-n-d between reagent additions. Also, use separate reservoirs for each reagent.
3           When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, a-n-d/or rotating the plate 180 degrees between wash steps may improve assay precision.
4           To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
5           Substrate Solution should remain colorless until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless to gradations of blue.
6           Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.

環(huán)保在線 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.kytsldc.cn,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),環(huán)保在線對(duì)此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購(gòu)買(mǎi)風(fēng)險(xiǎn),建議您在購(gòu)買(mǎi)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

請(qǐng) 登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
日本入室强伦姧人妻中文| 美女逼男逼小穴小骚下载| 亚洲男性天堂一区二区三区| 日韩精品无码一区二区三区不卡| 亚洲av一区二区在线看| 国产伦精品一区二区三区视频抖音| 啊啊啊好爽高潮啦| 在线观看日韩欧美| 中文字幕乱码一区二区三区麻豆| 天堂丝袜人妻中文字幕在线| 成人av大全免费一区二区三区| 插BB流水水视频| 让女人下面出水视频| 久久久国产了楼凤| 亚洲美女后入在线播放| 日韩精品一区av在线| 亚洲欧美一区二区爽爽爽| 日本一二区视频在线观看| 亚洲综合青青草原在线| 中文字幕av一区二区三区蜜桃| 日韩欧美视频在线观看不卡| 国产裸模大尺度私拍视频| 97超级免费视频在线观看| 国产伦精品一区二区三区视频抖音| 精品精品国产一区二区性色av| 中文字幕人妻一区二区三区人妻| 亚洲av无一区二区三区综合| 中文字幕无码区一区二区| av日韩在线观看一区二区三区| 九九在线精品亚洲国产| 大鸡巴干浪穴视频| 日本二区在线观看| 国产午夜福利片无码视频| 高清国产一区二区| 任你橹在线久久精品9| 精品区在线导航视频观看| 24日本精品视频免费| 麻豆国产欧美一区二区三区r| 欧美丰满大屁股女人的逼被操视频| 色一情一交一乱一区二区| 美女亚洲福利视频|