亚洲国产精品二区久久,日本美女后入式午夜视频在线观看,国产污视频在线观看,欧美日韩国产精品中文字幕在线观看

技術(shù)中心

Human Galectin 4人半乳糖凝集素4

2013年10月29日 15:55:35人氣:117來源:上海蔚霆生物科技有限公司

資料類型doc文件資料大小99328
下載次數(shù)14資料圖片 【點擊查看】
上 傳 人上海蔚霆生物科技有限公司 需要積分0
關(guān) 鍵 詞Human Galectin 4,人半乳糖凝集素4
【資料簡介】

上海逸晗生物科技有限公司代理不同品牌價格檔次的ELISA試劑盒。抗體產(chǎn)品等, 品種多,質(zhì)量好,價格實惠,并且還提供免費代檢測服務(wù)。
本公司的更多產(chǎn)品,請點擊公司:http://www.yihanbio.com/

Canine LN ELISA Kit

For the quantitative in vitro determination of Canine Laminin concentrations in

 serum - plasma - celiac fluid - tissue homogenate - body fluid

 

 

 

 

 

 

 

FOR LABORATORY RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

 

This package insert must be read in its entirety before using this product.

 

ELISA

ENZYME LINKED IMMUNOSORBENT ASSAY

 

INTENDED USE AND TEST PRINCIPLE

This LN ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of LN in the sample, this LN ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus LN concentration. The concentration of LN in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximay 2000×g. Remove serum and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1.  37 ℃ incubator

2.  Standard microplate reader capable of measuring absorbance at 450 nm

3.  Precision pipettes, disposable pipette tips and Absorbent paper

4.  Distilled or deionized water

 

REAGENTS PROVIDED

All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

 

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard(6 vial)

0.5ml/vial

0.5ml/vial

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20X Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note:

1.  Standard concentration was followed by:400,200,100,50,25,12.5ng/mL.

2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

 

PRECAUTIONS

  1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
  2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
  3. Do not use kit components beyond their expiration date.
  4. Use only deionized or distilled water to dilute reagents.
  5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
  6. Use fresh disposable pipette tips for each transfer to avoid contamination.
  7. Do not mix acid and sodium hypochlorite solutions.
  8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
  9. All samples should be disposed of in a manner that will inactivate viruses.
  10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
  11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.
  12. Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.
  13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

REAGENT PREPARATION AND STORAGE

Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

 

ASSAY PROCEDURE

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.

2.  Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.

3.  Add 100μl of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4.  Wash the Microtiter Plate 4 times.

Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.

5.  Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

6.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.

7.  Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

 

CALCULATION OF RESULTS

  1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.
  2. First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.
  3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
  4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
  5. Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.
  6. Assay range: 12.5 ng/mL –400 ng/mL.

7.  Sensitivity: The minimum detectable dose of Canine LN is typically less than 10 ng/mL.

8.  Cross-reactivity: This assay recognizes recombinant and natural Canine LN. No significant cross-reactivity or interference was observed.

9.  Storage: 2-8℃ (Use frequently); six months (-20℃)。

10.  Standard curve

 

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

上海蔚霆生物科技有限公司作者

上一篇:德國PICARD工具箱0025100

下一篇:美國ULTRANIOLET(UV)鎮(zhèn)流器TXG015B


我要投稿
  • 投稿請發(fā)送郵件至:(郵件標題請備注“投稿”)hbzhan@vip.qq.com
  • 聯(lián)系電話0571-87759680
環(huán)保行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺
環(huán)保在線APP

功能豐富 實時交流

環(huán)保在線小程序

訂閱獲取更多服務(wù)

微信公眾號

關(guān)注我們

抖音

環(huán)保在線網(wǎng)

抖音號:hbzhan

打開抖音 搜索頁掃一掃

視頻號

環(huán)保在線

公眾號:環(huán)保在線

打開微信掃碼關(guān)注視頻號

快手

環(huán)保在線

快手ID:2537047074

打開快手 掃一掃關(guān)注
意見反饋
啊好爽好多水深插射视频| 免费人成再在线观看| 黑人巨茎和中国美女视频| 97人妻精品一区二区三区视频| 国产剧情使劲操我逼| 成人 在线 欧美 日韩| 欧美激情在线播放第一页| 精品无码一区二区三区无码| 国产伦精品一区二区三区福利| 狗狗大鸡巴狂操美女| 一级做a爱过程免费视频俩| 久久精品国产自清天天线| 亚洲大尺度无码无码专线一区| 夜夜嗨av少妇一二三区| 精品一区二区三区乱码中文字幕| 女人18片毛片。| 强奸啪啪啪好大欧美| 任你橹在线久久精品9| 午夜精品福利一区二区三区蜜桃p| 妺妺坐在我腿上下面好湿| 男女操逼视频嫩嫩| 92婷婷伊人久久精品一区二区| 日本免费一区二区在线| 国产情侣色综合久久有码| 可以免费看污污片的软件| 日韩欧美一级特黄大片欧| 男生插女生下面流出白色精液视频| 成人毛片一级特黄| 欧美 亚洲 日本 国产| 啊啊啊啊大鸡巴操我视频| 啊啊啊好爽高潮啦| 啊好爽好多水深插射视频| 中文字幕国产精品一区二区三区| 狠狠五月激情综合去干网| 加勒比五月综合久久伊人| 激情五月六月婷婷俺来也| 日本十八禁大骚逼| 美女玩奶子和鸡巴| 国产精品一区二区在线观看91| 无码毛片一区二区本码视频| 大鸡巴射在穴穴里的视频|